Custom Search
 
  
 
TM 55-1905-222-14
Section III. UNIT TROUBLESHOOTING
4-5 TROUBLESHOOTING PROCEDURES.
This paragraph provides information useful in diagnosing and correcting unsatisfactory operation or failure of LCM-8
systems and equipment. Troubleshooting procedures in this manual are limited to the basic craft. Refer to TM 5-2815-
231-14 for engine and transmission troubleshooting procedures. Before using the troubleshooting procedures, ensure
that all applicable operating procedures have been performed.
NOTE
The table lists the common malfunctions which you may find during operation or
maintenance of the equipment.  You should perform tests/inspections and corrective
actions in the order listed.
This manual cannot list all malfunctions that may occur, nor all tests or inspections and
corrective actions. If a malfunction is not listed or is not corrected by the listed corrective
actions, notify your supervisor.
Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NAVIGATIONAL AIDS
1.
LIGHT(S) DO NOT LIGHT UP.
Step 1. Check for blown fuses.
Replace fuses (para 4-17).
Step 2. Check to see if wiring is faulty.
Check connections at connection boxes, control and distribution panel and at lights. Secure connections.
Step 3. Check to see if fixtures or switches are defective.
Replace fixtures and switches (para 4-7 and para 4-17).
4-6


 