TM 55-1905-222-14
Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM
1.
ALTERNATOR NOT CHARGING.
Step 1.
Test to see if voltage regulator/voltage protector is defective (para 3-5).
Replace voltage regulator/voltage protector (para 4-14).
Step 2.
Test to see if alternator is defective (para 3-5).
Replace alternator (para 4-12) Send defective alternator to direct support maintenance for repairs.
2.
ALTERNATOR OUTPUT LOW OR UNSTEADY.
Step 1. Test to see if voltage regulator/voltage protector is defective (para 3-5).
Replace voltage regulator/voltage protector (para 4-12/4-14).
Step 2.
Test to see if alternator brushes are loose.
Replace alternator (para. 4-12). Send defective alternator to direct support maintenance for repairs.
4-8
|
||