Custom Search
 
  
 
TM 55-1905-222-14
MAINTENANCE OF BATTERIES AND CABLES
4-10
TEST BATTERIES.
INITIAL SETUP
Test Equipment.
Equipment Conditions:
Tester, Battery GG-T-258 (Hydrometer)
References
Engine shut down.
TM 9-6140-200-14 (see Appendix A)
General Safety Instructions:
Disconnect all leads from battery
Terminals before testing.
TEST
1.
REMOVE LEADS FROM BATTERY TERMINALS.
a.
With engine shut down, remove battery box
cover.
b.
First disconnect negative battery lead (1) from
negative  terminal  of  battery  (2).
Then
disconnect positive battery lead (3)
from
positive terminal of battery (2).
2.
TEST BATTERY.
a.
Remove cell cover (4).
b.
Test the specific gravity of each cell with a
hydrometer, and compare reading to chart in
TM 9-6140-200- 14.  If the specific gravity
reading is below 1225 on the hydrometer,
charge the battery. Specific gravity readings of
1.260-to-1270  on  the hydrometer indicate a
fully charged battery.
c.
Install cell cover (4).
4-21


 