5-6 REPAIR ALTERNATOR (Continued).
CLEANING
CLEAN BRUSH ASSEMBLY
a.
Dust off brush assembly with a soft brush.
b.
Clean brush cover plate with a clean lint-free
cloth.
c.
Clean brush assembly cavity with a clean lint-
free cloth.
INSPECTION
INSPECT BRUSH ASSEMBLY
a.
Visually inspect brush for cracks, excessive
wear and other defects.
b.
Get a new brush assembly if above conditions
are found.  If brushes are not oil soaked or
cracked, and the rotor contacting surfaces are
smooth, and the unused brush length is 3/16
inch or longer, they may be reused.
TESTING
TEST BRUSH ASSEMBLY
Test brush assembly for continuity and no circuit
using a multimeter.
5-14


 