Tweet |
Custom Search
|
|
|
||
TM 55-1905-222-14
5-41
REPAIR BILGE PUMP/HYDRAULIC MOTOR ASSEMBLY (Continued).
2. DISASSEMBLE HYDRAULIC MOTOR
a. Remove shaft drive key (30) from the shaft (31).
b. Remove four screws (32) from the face of the
mounting flange (33). Remove mounting flange
(33).
c. Remove shaft dirt seal (34), high pressure
shaft seal (35), 'O' ring (36), retainer rings (37),
thrust bearing (38) and washers (39).
d. Remove six screws (40), and lockwashers (41)
securing the front bearing housing (42) to the
motor body (43).
e. Separate front bearing housing (42) from
motor body (43); remove body and housing 'O'
rings (44 and 45).
f.
Remove four locating dowels (46) from the
gerotor housing (47).
g. Remove gerotor drive key (48) and gerotor (49).
h. Remove retainer rings (50 and 51). Do not
remove roller bearings (52 and 53) from shaft
(31). If not defective.
i.
Remove end plug (54) and 'O' ring (55) from
motor body (43).
j.
Remove two check valve plugs (56), spring (57)
and check valve poppets (58) from the motor
body (43).
k. Remove external drain plug (59) from motor
body (43).
5-105
|
||