11 Fire station No. 1 (34). Fire station for the engine room using seawater. Has 50 feet of 1-1/2 inch
hose with an all-purpose nozzle.
12 Tunnel vent fan controller (35). Motor controller for tunnel vent fan.
13 Ventilation control center (36). Four motor controllers for engine room ventilation.
14 Fire pump controllers (37). Motor controllers for the fire pump number 1 and pump number 2.
15 Auxiliary Machinery Controller Center (38). Central locatioor fdifferent motor controllers.
n
16 Sludge Tank Indicator (39). Tank level indicator for the sludge tank.
17 General alarm light (40).
Red light provides visual indication of general alarm status.
18 Foam Eductors (41). Controls to the foam supply tank.
19 Foam Fire Station No. 1 (42). Fire station for the engine room with seawater or foam. Has 50 ft of 2-
1/2 inch hose with an all-purpose nozzle.
20 Store room (43). Store room for spare parts.
21 Fire pump motor switch (44). Two STOP-START type I motswitch for the fire pumps.
or
22 Tank level indicators (45). Indicators for the fresh water tanks and the ballast tanks.
23 Battery storage box (46). Two battery storage boxes provide backup power to start the starboard
SSDG (50).
24 Fire pump gauges (47). Pressure gauges for the fire pump discharge.
25 Battery charger (48). Battery charger for the starboard generator batteries.
26 Electric fire pumps (49). Seawater fire pumps to pressurize the fire main.
27 Starboard ship service generator (50). Bat y started and fresh water cooled diesel engine for the
ter
starboard ship service generator.
28 Bilge/ballast pump (51). Pump to ballast the LCU and/or pump the bilges.
29 Seawater circulating pump (52). Pump that circulates seawater for the stern tubes, marine sanitation
device, water makers, and air conditioning system.
30 Bilge/ballast pump controller (53). Motor controller for the bilge/ballast pump.
1-56
|
||