Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Emergency Generator Diesel Engine Control Panel (FIGURE 2-44)
1
ELAPSED TIME
Records cumulative time of engine operation.
HOURS
1/10
2
HIGH WATER
Circuit breaker opens when engine shuts down for
TEMPERATURE
high water temperature.
3
TEMP
Indicates engine water temperature.
4
OIL
Indicates oil engine pressure.
PSI/KP
5
LOW OIL
Circuit breaker opens when engine shuts down for
PRESSURE
low oil pressure.
6
FAULT
Push to by-pass. To reset, turn RUN-OFF-
BY-PASS
AUTO switch to OFF (amber).
7
OVERCRANK
Circuit breaker opens when engine shuts down for
OVERCRANK condition.
8
OVERSPEED
Circuit breaker opens when engine shuts downfor
OVERSPEED
condition.
9
RUN-OFF-AUTO
Set to RUN for manual operation; AUTO for normal
operation.
10
STARTER
Circuit breaker opens for malfunction in starter
GOVERNOR
or governor wiring systems.
11
CONTROL
Circuit breaker opens for short in control panel
wiring.
12
EMERGENCY
Push to stop engine. Turn clockwise to reset.
STOP
13
ENGINE
Illuminates when any circuit breaker opens
FAULT
(red).