Custom Search
 
  
 
TM 55-1905-223-10
Table 2-2. Operator/Crew Preventive Maintenance Checks and Service - CONT
B - Before
D - During
A - After
W - Weekly
M - Monthly
INTERVAL
PROCEDURES
EQUIPMENT IS
ITEM
ITEM TO BE
CHECK FOR AND HAVE REPAIRED
NOT READY/
NO
B
DA W M
INSPECTED
OR ADJUSTED AS NECESSARY
AVAILABLE IF:
76
Portable Fire-
fighting Pump
Model PE-250 -
continued
Exhaust Hose
Exhaust system
l
WARNING
leaks.
Do not operate pump in closed
area without exhaust hose
connected and routed safely to
outside fresh air.
Check that exhaust hose and
gaskets are tight and sealed
properly with no leaks.
Fuel Line
Check hose connection for
Class III
l
proper direction of fuel flow.
leaks.
Priming Pump Oil
Check oil level; fill if low.
Low oil level.
l
l Spark Plugs
Check condition of spark plugs.
l Pump Exterior
Visually inspect pump for
damage and condition.
Fuel Tank
Check level of fuel in tank.
l
NOTE
Fill gas tank with a mixture of
2 cans of BIA-TC-W oil and 6
gallons of 090 octane gasoline.
Steering Gear
Compartment
77
l Steering Gear
Inspect the steering gear and
Steering gear
l
l
and Linkage
linkage for broken or worn
does not oper-
parts.
ate smoothly.
2-251


 