Custom Search
 
  
 
TM 55-1905-223-10
Table 2-2. Operator/Crew Preventive Maintenance Checks and Service - CONT
B - Before
D - During
A - After
W - Weekly
M - Monthly
INTERVAL
PROCEDURES
EQUIPMENT IS
ITEM
ITEM TO BE
CHECK FOR AND HAVE REPAIRED
NOT READY/
NO
B
DA W M
INSPECTED
OR ADJUST AS NECESSARY
AVAILABLE IF:
97
Ship's Service
Diesel Generator
(STBD) -
continued
Battery
Check gauge for normal reading
(22-26V).
Throttle
Check for binding, loose
(Actuator)
fittings, and capscrews that
affect the smooth operation of
the throttle throughout its
range. Refer defects to unit
maintenance.
Exhaust System
a.
Check for exhaust leaks.
Exhaust system
Refer leaks to unit
leaks.
maintenance.
b.
Check for corrosion and
clean as required.
Soot Trap
Open inspection door, clean out
soot.
Generator
Make sure that air intakes and
vents on the generator housing
are free from dirt, debris, and
other foreign materials.
Engine (General)
a.
Visually check for air
Class III
water, fuel or oil leaks.
leaks.
b.
Tighten any loose
connections, fittings or
capscrews.
c.
If unserviceable, refer to
unit maintenance.
2-267


 