Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-10
c. Fresh Water Piping System (FIGURE 2-112).
(1) Align Fresh Water Piping System at the fresh water (FW) tanks and pumps as
_, follows:
(a) Open FW-8, ISNL/SUCT-TK FW-6P (4).
(b) Open FW-7, ISLN/SUCT-TK FW-6S (8).
(c) Open FW-10, FW PUMP NO. 2 SUCT FR FW TKS (26).
(d) Open FW-9, FW PUMP NO. 1 SUCT FR FW TKS (24).
(e) Open FW-12, FW PUMP No. 2 DISCH (19).
(f) Open FW-11, FW PUMP No. 1 DISCH from Pump (25).
(g) Open FW-13, PRESSURE ISLN (20).
NOTE
In fresh water piping systems all other valves are for equipment repair or fresh water use.
(2) In Engine Room at Fresh Water Motor Controllers (FIGURE 2-113) perform the following:
(a) P217 Motor Controller.
1 Set circuit breaker HANDLE (1) to ON position.
2 Set HAND-OFF-AUTO switch (2) to AUTO position.
3 Press START (3) pushbutton.
(b) P218 Motor Controller.
1 Set circuit breaker HANDLE (1) to ON position.
2 Set HAND-OFF-AUTO switch (2) to AUTO position.
3 Press START (3) pushbutton.
d. Water Purification System.
(1) Align Fresh Water Piping System (FIGURE 2-112) as follows:
(a) Open BB-22, ISLN SEACHEST.
(b) Open BB-35 SEACHEST VENT ISOLATION and BB-36 SEACHEST VENT.
(c) Open FWM-1, ISLN-SW SUPPLY TO FW MAKERS (11).
(d) Open FWM-2, SW SUPPLY TO FW MAKER NO. 2 (14).
2-342
|
||