Custom Search
 
  
 
TM 55-1905-223-10
(6) If the Fuel Filter/Coalescer is to be used, open FO-47, FILTER/SEPARATOR INLET (31) and FO-
51, FILTER/SEPARATOR OUTLET (7).-
(7) If the Fuel Filter/Coalescer is NOT to be used, open FO-48, BY-PASS
FILTER/SEPARATOR (34).
(8) Align tank that fuel is to be pumped from as follows:
(a) F-3P, open FO-21 and FO-26, SUCT FM TK F-3P (53 and 43).
(b) F-3S, open FO-22 and FO-25, SUCT FM TK F-3S (54 and 40).
(c)
F-4P, open FO-19 and FO-24, SUCT FM TK F-4P (52 and 42).
(d) F-4S, open FO-20 and FO-23, SUCT FM TK F-4S (47 and 41).
(e) F-7P, open FO-15 and FO-28, SUCT FM TK F-7P (50 and 21).
(f)
F-7S, open FO-16 and FO-27, SUCT FM TK F-7S (49 and 19).
(g) F-12P, open FO-18 and FO-34, SUCT FR DAY TK F-12P (48 and 24).
(h) F-12S, open FO-17 and FO-35, SUCT FR DAY TK F-12S (51 and 16).
(9)
Align tank that is to receive fuel as follows:
(a) F-3P, open FO-6, SUPPLY TO TK F-3P (58).
(b) F-3S, open FO-8, SUPPLY TO TK F-3S (57).
(c) F-4P, open FO-5, SUPPLY TO TK F-4P (59).
(d) F-4S, open FO-9, SUPPLY TO TK F-4S (61).
(e) F-7P, open FO-12, SUPPLY TO TK F-7P (55).
(f)
F-7S, open FO-13, SUPPLY TO TK F-7S (63).
(g) Bowthruster, day tank, open FO-7 and FO-30, SUPPLY TO BOWTHRUSTER DAY TK (60 and 44).
(h) Emergency -generator day tank, open FO-II, SUPPLY TO EMER GEN DAY TK (62).
(i)
F-12P, open FO-10, SUPPLY TO DAY TK F-12P (56).
(j)
F-12S, open FO-14, SUPPLY TO DAY TK F-12S (64).
(k) Turn on tank level indicators, (FIGURE 2-168) by setting POWER switch (1) to ON position.
(l)
On Fuel Transfer Pump Motor Controllers (FIGURE 2-169), set circuit breaker (1) to ON position.
2-480


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business