Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-10
(5) Open FM-26, NO. 2 FIRE PUMP STRAINER ISOLATION (14).
(6) Open FM-18, FIRE PUMP NO. 1 SUCT (16).
(7) Open FM-25, NO. 1 FIRE PUMP STRAINER ISOLATION (15).
(8) Open FM-15, NO. 2 FIRE PUMP DISCH (10).
(9) FM-14, NO. 1 FIRE PUMP DISCH (11).
(10) Open FM-13, FIRE MAIN & BALLAST CROSS CONN (28).
(11) Ensure the following valves are closed:
(a) BB-19, DISCH TO SLUDGE TK (34).
(b) FM-12, FOAM STA 1 & STBD MONITOR ISLN (42).
(c) FM-11, FOAM STA 2 & PORT MONITOR ISLN (43).
(d) FM-10, FIREMAIN ISLN (41).
(e) FM-20, EMER FIRE PUMP DISCH (44).
(f) BB-38, CROSS CONN FIRE PUMP SUCT TO BILGE MANIFOLD (27).
(g) BB-37, CROSS CONN SUCT TO BILGE MANIFOLD (26).
(h) BB-24, SUCT-BILGE BALLAST PUMP (20).
b. Operate fire pumps by pressing START (1, FIGURE 2-252) on fire pump motor switches.
c. When the selected tank has reached the desired level on the tank level indicator (located in the
starboard-forward corner of the engine room) press the STOP pushbutton (2).
d. Restore Valve Alignment (FIGURE 2-251).
(1) Close the following valves:
(a) BB-18, OVBD DISCH (37).
(b) BB-27, TO OVBD DISCH (8).
(c) BB-15, SUCT FR SW-1 AND SW-2S AND SW-2P (1).
(d) BB-1, ISLN TK SW-1 (37).
(e) BB-2, ISLN TK SW-2P (36).
(f) BB-3 ISLN TK SW-2S (38).
(g) BB-7, SUCT FR SW-5S AND SW-5P (3).
2-661
|
||