Custom Search
 
  
 
TM 55-1905-223-10
Standard: Door locks operational, door fits and seals properly, hold back hooks and eyes present and
functional. Windows clear and undamaged, no evidence of leakage at window gaskets. _________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
c.
Inflatable Life Rafts, (2 or 3):
Condition: Inspect for presence, painter condition, attached to vessel properly, damage to container and
securing straps. Observe or check vessel records for repack date, repack date may be under rubber hand,
check condition of rubber band (Navy raft).
Standard: Either 3-fifteen man rafts or 2-twenty five man rafts must be onboard, fixed in cradles with
hydrostatic releases and painters attached. Rafts must have inspection date not more than 4 years prior to
current date, if Navy style, 1 year if commercial style. Cases and rubber hand (Navy) must be undamaged.
Painter not frayed or cut and securely made fast to vessel. _______________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
d.
Hydrostatic Releases:
Condition: Check for presence, damage, proper attachment. If commercial type, inspection date.
Standard: Each life raft must have hydrostatic release fitted, show no evidence of damage or tampering and be
properly secured to vessel and raft band. Commercial type must have inspection date not more than 1 year
prior to current date.
e.
EPIRB:
Condition: Inspect for presence. Verify operation, battery expiration date, hydrostatic release expiration date,
and annual registration.
Standard: Verify operation by self test, verify battery and hydrostatic release expiration dates (5 year battery, 2
year hydrostatic release) verify annual registration tag is present and not expired. ______________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
Change 8 G-14


 