Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-10
m.
Antenna, Stbd Aft 35 Ft. Whip HF:
Condition: Inspect ground strap, mounting, warning placard, whip.
Standard: Ground strap present, secure and in sound condition. Mountings all present and secure, warning
placard present, whip in good condition no damage or deformation:
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
n.
Antenna, Port Aft 35 Ft. Whip HF:
Condition: Inspect ground strap, mounting, warning placard, whip.
Standard: Ground strap present, secure and in sound condition. Mounting all present and secure, warning
placard present, whip in good condition no damage or deformation:
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
o.
Fire Station No. 7:
Condition: Inspect hose for test date and pressure and vessel designation marking, shut off valve and nozzle,
handle for operating and condition, condition of cabinet and hose, coupling spanner wrench, fire ax. Fire ax
marked with vessel designation. Placard indicating station number posted.
Standard: Hose marked with test date and pressure within previous 12 months also marked with vessel
designation, shut off valve and nozzle handle operates freely, nozzle is clear, cabinet free of corrosion, sound
and hinges and latch in serviceable condition, coupling spanner wrench and fire ax present and in serviceable
condition, marked with vessel designation. Placard reading "Fire Station No. 7" posted and legible. _______
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
p.
Battery Box and Batteries:
Condition: Inspect for corrosion and condition of connections and cables, missing caps electrolyte level,
condition of box and securing devices, no smoking placard.
Change 8 G-17
|
||