Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-10
10.0 Main Deck Enclosures - Forward.
10.1 Stbd Side (Bosn Locker).
a.
Ramp Winch:
Condition: Test operate and inspect, raise and lower ramp from all control stations, observe latch and wildcat
operations during test. Check operation of cable slack switch, and check that winch guards are in place and
functional. Verify accomplishment of PM services.
Standard: Ramp can be lowered and raised from each control station. Ramp latch, latches and releases
without binding, and is not worn, wildcat lugs or bushing are not worn excessively. Winch and cable guards are
in place and functional. Cable slack switch operates to stop winch on slack cable conditions.
Verify accomplishment of PM services of:
Annual: Change oil in winch gear reduces and inspect hydraulic pump flexible coupling insert.
Bi-annual: Change hydraulic fluid and clean suction strainer element.
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
b.
Escape Trunk Ladder:
Condition: Inspect for proper securement, condition and serviceability and obstruction.
Standard: Properly secured, no damage or deterioration which effects serviceability, access to ladder is not
obstructed.
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
c.
Sound Powered Telephone:
Condition: Inspect for condition of cabinet, bell and instrument.
Change 8 G-67
|
||