TM 55-1905-223-10
Check safety controls
Remove and clean magnetic pick up
Check coolant heater for corrosion
Drain and refill waterjet hydraulic system
Drain and refill waterjet lube oil system
Lubricate waterjet drive shaft
36 Month
Replace injectors (as needed)
Replace fuel pump (as needed)
Check turbo-charger clearances
Replace coolant pump and idler pulley assembly (as needed)
Replace engine sea water pump (as needed)
Drain, flush and replace coolant
Check crankshaft end play
Standard: No leaks in lube oil, fuel oil, water or exhaust systems. After engine is warmed up engine oil
pressure should be at least 17 psi at 1800 RPM and pressure should be approximately 50 psi, water
temperature less than 215F, normal 160-200F. Oil temperature less than 225F. Engine can be started
and controlled from both pilot house and local control. Engine does not vibrate excessively. Bowthruster
responds smoothly to both control stations and direction indicators accurately indicate direction of thrust. Fire
pump clutch engage and disengages pump. Fire pump capable of maintaining a pressure of 125 psi in closed
discharge valve test and capable of spraying streams of at least 40 ft from 2 fire hoses at stations on the
uppermost deck. Log indicates accomplishment of all required P/M services as applicable (annual services at
interim inspection, annual services and 36 month services at Pre-OCCM inspection). ___________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
j.
Intercom:
Condition: Inspect visually for damage, and completeness.
Standard: No damage, all components intact. __________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
Change 8