Custom Search
 
  
 
TM 55-1905-223-24-1
d.
To remove bypass tube assembly, perform the following steps.
(1)
Remove two hexagon head capscrews (49, FIG. 2-12) and lockwashers (50) retaining
metal bypass tube assembly (58) to the housing (44).
(2)
Remove gasket (51) and discard.
(3)
Remove two hose clamps (52) retaining metal bypass tu e assembly (58) to nonmetallic
b
hose (57). Remove bypass metal tube assembly (58) and non-metallic hose (57).
(4)
Remove two hexagon head capscrews (54) and lockwashers (55) retaining the opposite end
of metal bypass tube assembly (53).
(5)
Remove metal bypass tube (53) and gasket (56). Discard gasket.
e.
To remove the water transfer connection piping, perform the following steps.
(1)
Remove pipe plug (6, FIG. 2-11).
(2)
Remove four hexagon head capscrews (1 and 3), lockwashers (2 and ), and nuts (19).
4
(3)
Remove tube braces (5).
(4)
Remove the water transfer connection (7).
f.
To remove water transfer metal tube assembly, perform the following steps:
(1)
Remove two hexagon head capscrews (5, FIG. 2-12) and lockwashers (6) retaining water
transfer tube (4) to the after cooler.
(2)
Remove preformed packing (7) and discard.
(3)
Remove two hexagon head capscrews (3) and lockwashers (2) retaining water transfer tube
(4) to thermostat housing support (44).
(4)
Remove preformed packing (1) and discard.
(5)
Remove water transfer metal tube assembly (4).
g.
To remove the water inlet transfer tube assembly, perform the following steps.
2-52


 