Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-1
NOTE
For the left bank housing the end of the tubes with two grooves must be installed in
the bore that is positioned toward the front of the engine. For the right bank
housing the end of the tube with two grooves must be installed in the bore that is
positioned toward the rear of the engine.
(4) Use a water tube driver (1, FIG. 2-13) and a hammer to push the water tube into the
adjacent housing until the groove is visible.
(5) Position preformed packing (34, FIG. 2-12) and install metal /tube assembly (26) on
water connection (27).
(6) Secure metal tube assembly (26) with lockwashers (25) and machine bolts (24). Tighten
bolts to 15 ft-lb (20 N ).
m
(7) Position two preformed packings (21 and 35) and instal next segment of tube assembly (22).
l
(8) Install retaining ring (23).
(9) Position two pipe plugs (37) in water transfer expansion plugs (36 and 38). Attach water
transfer expansion plugs with ring spacers (18), lockwashers (19) and hexagon head
capscrews (20). Tighten capscrews to 15 ft-lb (20 N m).
(10) Position preformed packing (17) and install next segment of tube assembly (16).
(11) Install retaining ring (15).
(12) Position three preformed packings (12 and 14). Instal the next two segments of tube
l
assembly (9 and 13).
(13) Position two preformed packings (8). Install last segment of tube assembly (47).
(14) Install water inlet transfer tube assembly (47) to thermostat housing (44). Secure with
lockwashers (10) and machine bolts (11). Tighten bolts to 30 ft-lb (40 N m).
(15) Position two preformed packings (39 and 42).
(16) Install transfer tube (40).
(17) Install retaining ring (41).
c.
To replace water transfer metal tube assembly,perform the following steps:
(1) Position preformed packing (1, FIG. 2-12).
(2) Position water transfer metal tube assembly (4) on thermostat housing support (44).
2-57
|
||