Custom Search
 
  
 
TM 55-1905-223-24-10
2-21. Replace Emergency Handcrank. (FIGURE 2-7)
This task covers: a. Inspection, b. Removal, c. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
TM 55-1905-223-10, bow ramp assembly
shut down, tagged "Out of Service -
Do Not Operate."
Materials/Parts
NOTE
Emergency handcrank handle
P/N 286239
When not in use, the emergency handcrank
Screw, self-locking
is stored in a remote area.
INSPECTION
a. Inspect crank housing (6) for corrosion or other evidence of broken parts.
b. Turn crank handle (5) listen for ratchet dog engaging ratchet wheel teeth.
c. Check crank handle for secure mounting and freedom of movement.
REMOVAL
a. Pull manual release lever "T" handle (4) on hand pump (2).
b. Set shutoff hand valve (2, FIGURE 2-5) fully clockwise; closed.
c. Turn emergency hand crank handle (5) in both directions to ensure winch is locked in position.
d. Remove three screws (3) securing emergency hand crank to manual interlock switch (1).
e. Remove handcrank (5).