TM 55-1905-223-24-10
REPAIR
WARNING
The fumes from cleaning solvents are dangerous. Use solvents in open air or in
well ventilated space. Wear proper eye protection and rubber gloves.
a. Clean equipment and windings using a suitable cleaning solvent.
b. Protect windings and machined surfaces; clean equipment housing, fan, interior and exterior of end bells (2), (8)
thoroughly, leaving no residue or injurious effects.
c. Dry the equipment by placing it in an oven at 230 degrees Fahrenheit for 10 hours.
d. Visually inspect for cracks, unbonded insulation, and discoloration of one coil from associated coils.
ASSEMBLY
a. Install new gasket (10) onto box lid (11) and install onto conduit box (9).
b. Install rotor and shaft assembly (6) endplate (7) and bolts (8) onto stator assembly (5).
c. Install front endplate (4) into stator assembly (5).
d. Install fan cover (1) and tighten four retaining screws.
4-6
Change I