Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-11
SYMPTOM INDEX-CONT
Troubleshooting
Procedure
MOTOR
Motor energized; pump shaft fails to turn
Item 14
REMOTE STATUS INDICATOR
Pump, motor, and high level warning lights
flashing in sequence with the exception
of one or more lights
Item 7
Pump light constantly lit
Item 5
SANITARY UNIT
Unit working, but processes slowly
Item 17
SYSTEM
Not operating; all lights OFF
Item 6
UNIT
Operates only in continuous (manual) mode
Item 9
Stops; fails to run in any mode
Item 8
WASTE DISPOSER
Noisy or vibrates excessively
Item 15
Table 2-1 lists the common fault conditions that may be found during operation or maintenance of the
equipment. Look for causes and do corrective actions in the order listed. This manual cannot list every
symptom that may show up, and it cannot list all the possible causes and corrective actions. If a symptom is
not listed, or if it keeps up after you have performed the corrective actions, notify your supervisor.
2-14
|
||