Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-11
2-26. Repair Bleach Tank Assembly.
This task covers:
a. Inspection/Service,
b. Removal,
c. Repair,
d. Replacement.
INITIAL SETUP:
Tools
Equipment Condition
Tool kit, general mechanic's
Electrical power OFF and tagged
to the sanitary unit
Materials/Parts
Bleach tank assembly P/N 3700019
Container, 10 gl, closable
(for draining old tank)
Warning tags, Item 10, Appendix C
Bleach, Item 13, Appendix C
INSPECTION/SERVICE
Inspection and service on the bleach tank assembly is accomplished through PMCS.
REMOVAL
NOTE
The bleach tank is located separately from the sanitary main
unit. A 1/4-inch gravity feed line is attached from the tank to the
metering valve on the unit (3, FIGURE 2-24).
a. Close the metering valve on the main unit by turning clockwise.
b. Remove the fill plug (2, FIGURE 2-26) from the adapter (1) in the tank (3).
WARNING
Avoid splashing bleach in eyes when disconnecting lines.
c.
Disconnect the bleach line (7, FIGURE 2-24) at the metering valve connection (5), and drain the bleach
from the tank into a portable
2-96
|
||