Custom Search
 
  
 
Table 2-1.
Preventive Maintenance Checks and Services
A - Annually
S - Semiannually
Q - Quarterly
D - Daily W - Weekly M - Monthly
Items To Be
Interval
Item
Procedures
Inspected/
No.
D
W
M
Q
S
A
Serviced
DOORS, HATCHES, AND MANHOLES/WINDOWS GROUP - CONT
q
NOTE
Watertight
66
Hatches and
Operating handle or dog-spindles
Scuttles CONT
that penetrate through watertight
closure frames or panels should
not have grease fittings, in lieu
of stick-packing plungers, for
accomplishing packing of the
spindle.  A through spindle packed
with general purpose grease is not
watertight; therefore, grease
fittings must be used only on non-
penetrating spindles.
(12) Lubricate dog or handwheel shafts:
(a) Screw packing plunger several turns to force
existing lubricating stick packing out and
around spindle. If stick packing has been
completely used up, the packing plunger will
not screw in any further and stick packing
(Item 33, Appendix C) must be replenished as
follows:
1 Remove packing plunger from spindle.
2 Insert stick packing in shaft opening.
3 Push stick packing deep into shaft opening
using a 1/4-inch diameter rod.


 