Custom Search
 
  
 
TM 55-1905-223-24-18-1
Troubleshooting - CONT
Table 2-2.
Malfunction
Test or Inspection
Corrective Action
ELECTRIC FOOD MIXER - CONT
STEP 2.  Check if mixer load is too great.
Stop mixer, shift to another speed and restart mixer.
31. Unit runs hot or smokes.
STEP 1.  Check for low oil in gear box.
Drain out old oil, remove cover plate and add three pints SAE 50 oil (Item
21, Appendix C).  Refer to LO 55-1905-223-12.
32. Attachments strike bottom of bowl.
STEP 1.  Check if bowl support is out of adjustment.
Replace bowl support, para. 2-59.
33. Attachments strike sides of bowl.
STEP 1.  Check for bent attachments or dented bowl.
Replace as required, para. 2-59.
34. Bowl will not raise.
STEP 1.  Check for defective drag link shaft.
Repair column and base assembly, para. 2-59.
35. Transmission operates with a skipping motion (fluctuating speed).
STEP 1.  Check for overloaded unit.
Shift to lower speed or reduce quantity of material being mixed.
36. Bowl support hard to raise and lower.
STEP 1.  Check for bowl support binding on bowl slides.
Clean bowl slides and lubricate with light grade oil (Item 20, Appendix C)
Refer to LO 55-1905-223-12.
NOTE
Troubleshooting procedures are common to all
refrigerators and freezers.  Refer to Index
for appropriate repair paragraphs.