Custom Search
 
  
 
TM 55-1905-223-24-18-1
Troubleshooting - CONT
Table 2-2.
Malfunction
Test or Inspection
Corrective Action
CENTRAL PUMP UNIT (FRESH WATER) - CONT
Check start and stop pushbuttons on engine room console panel for
STEP 2.
online (main) or (standby) pump.
Reset pushbuttons to start either (main) or (standby) pump.
STEP 3.  Check for improper control setpoint on pressure switch.
Ensure pressure switch turn ON/OFF respective (main) or (standby) pump when
tank pressure rises to and drops below the control setpoint.
Check for loose connection(s) or defective electrical wires/cable(s)
STEP 4.
between engine room console panel and pump motor.
Tighten loose connection(s).  Replace electrical wires/cable(s).
(TM 55-1905-223-24-1812).
STEP 5.  Check for defective motor.
Replace motor, para. 2-95.
57. Noisy pump/motor operation.
STEP 1.  Check for air or gas in liquid.
Identify source and correct problem.
STEP 2.  Check for liquid vortexing (cavitation) in casing.
Release trapped air from pump casing.
STEP 3.  Check for dry bearings.
Grease pump/motor bearing(s) (Lo 55-1905-223-12).
STEP 4.  Check for loose or broken mounting bracket and bolts.
Tighten loose mounting bracket.  Replace bracket/bolts.
STEP 5.  Check for damaged pump/motor.
Replace pump/motor, para. 2-95.
CENTRIFUGAL PUMP UNIT (FRESH WATER BOOSTER) AND
(REDUCTION GEAR COOLING WATER)
58. Low discharge pressure.
STEP 1.  Check for liquid vortexing (cavitation) in casing.
Release trapped air from pump casing.
STEP 2.  Check for air or gas in liquid.
Identify source and correct problem.
2-124


 


Privacy Statement - Copyright Information. - Contact Us