Custom Search
 
  
 
TM 55-1905-223-24-18-1
Table 2-2.
Troubleshooting - CONT
Malfunction
Test or Inspection
Corrective Action
RUDDER ANGLE INDICATOR (RAI)
69. All indicators move in the wrong direction when the rudder is turned.
STEP 1.  Inspect wiring in junction box for correct corrections.
Reverse connections at terminals 4 and 6 in junction box, see junction box
wiring diagram.
Junction Box Wiring Diagram .
70. One indicator of a multiple station system moves in the wrong direction when the
rudder is turned.
STEP 1.
Inspect wiring in indicator that moves in wrong direction of proper
connections.
Reverse brown and white wires on faulty indicator. See rudder angle
indicator wiring diagram.
2-132


 