Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-18-1
Replace Pressure Switch Assembly.
2-24.
a. Removal, b. Replacement, c. Adjustment.
This task covers:
INTIAL SETUP
Equipment Condition
Tools
E l e c t r i c a l power to lube oil purifier
Tool kit, general mechanic's,
turned OFF at P205 power/lighting
panel and tagged "Out of Service - Do
Not Operate."
Materials/Parts
Pressure switch assembly
P/N HYA-188-042
Warning tags, Item 1, Appendix C
REMOVAL
Tag and disconnect electrical wires at conduit (2).
a.
Unscrew switch cover (1) by turning counterclockwise and remove.
b.
c.
Remove four bolts (5) and remove pressure switch (8) from transducer (6).
REPLACEMENT
Secure with four
Position pressure switch assembly (8) on transducer (6).
a.
b o l t s (5). Torque to 80 in-lb (100.4 Nm).
Remove adjusting nut cover (7) by lifting and twisting it slightly.
b.
ADJUSTMENT (Table 2-4)
I f the fixed differential pressure switch is in the line of final application
a.
when adjustment is made, be sure pressure switch can be test operated without
affecting other equipment.
Loosen lock ring (3) on adjustment nut (4) and turn pressure adjustment nut
b.
full upwards using a 7/16 wrench.
2-221
|
||