Custom Search
 
  
 
TM 55-1905-223-24-18-1
Repair at this level of maintenance is by replacement of: Gaskets (5, 10, 13,
and 19), preformed packing (9) and spiral torsion spring (12). Contact kit
needed for repair of rotary switch.
a.
Attach cover (17) on housing (11) with machine screws (14).
Install adjusting screw (16) and plain hexagon nut (15).
b.
Attach cover (8) with machine screws (2).
c.
d.
Squeeze lever switch (4) and install switch handle (3) on shaft.
Tighten hexagon capscrew (6).
e.
Attach rotary switch with mounting screws.
a.
Thread electrical leads through hole in bottom of electrical connector
b.
box (18).
Remove tags and connect electrical leads.
c.
Replace cover (7) with machine screws (1) on electrical connector box.
d.
e. Remove tag and turn on electrical power at the emergency lighting
panel.
Test horn.
f.
2-285


 