TM 55-1905-223-24-18-1
Install thermostatic switch (8) in junction box (7). Secure with mounting
a.
hardware.
Connect electrical leads (9) to thermostatic switch. Remove tags.
b.
Install water switch (6) and secure with mounting hardware.
c.
Connect electrical leads (5) to water switch. Remove tags.
d.
Install electrical bell (4) on terminal box (1). Secure with hex head nut
e.
(3).
Connect electrical cable (2) to electrical bell.
f.
Restore power to shipboard panel alarm at EP102, circuit breaker 9. Remove
g.
tag.
Notify the bridge that maintenance on the shipboard panel alarm system is
h.
complete.
2-575


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business