Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-18-1
2-200.
Replace/Repair Generator Number One Battery Assembly.
This task covers:
a. Removal, b. Repair, c. Replacement.
INITIAL SETUP
Tools
Equipment Condition
T o o l kit, electrician's,
SSDG-2 BATT CHGR EP112 40AT
circuit breaker OFF and tagged
"Out of Service - Do Not Operate."
Materials/Parts
TM 55-1905-223-10.
Battery P/N COM-5D
Warning tag, Item 1, Appendix C
The eight batteries in this bank are
connected in parallel. Be sure to tag
cables before removal so that they can be
installed in the correct location. Maximum
output voltage to the engine starter should
not exceed 24 volts DC.
Refer to procedures in paragraph 2-194 for removal, repair and replacement of
battery.
2-666