Custom Search
 
  
 
TM 55-1905-223-24-18-1
Repair at this level of maintenance is by replacement of controller motor (4),
controller motor (remote) (5), gasket (8), electrical power cable (12), single
leg wire rope assembly (3).
a.
Install motor controller (remote) (5).
b.
I n s t a l l motor controller (4).
c . Install conduit box (8) and gasket (9).
d.
Install hexagon capscrews (10) and lockwashers (11).
e . Install electrical power cable (12).
f.
I n s t a l l electrical fitting (1,6) and apply sealer.
Attach single leg wire rope assembly (3) to winch assembly (2).
g.
h.
Turn ON electrical power at deck switch (7) and retract wire rope assembly to
winch assembly.
2-736


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business