Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-18-1
h.
Remove motor controller panel (15) from enclosure.
a.
Position motor controller panel (15) over mounting screws on enclosure.
Install three plain hex nuts (4) and flat washers (5) and secure motor
b.
controller panel to enclosure.
Direct (external wiring) through opening at top of enclosure.
c.
Connect electrical leads to motor starter (16), terminal board (14), rotary
d.
switch (6) and transformer (3), (external wiring). Remove tags.
Connect electrical leads to push switches (13) on rear of front panel flange.
f.
Position switch handle assembly (12) on front panel flange.
g.
Engage switch handle with trip bar (7) on rotary switch (6).
h.
Install two machine screws (11), lockwashers (10) and plain hex nuts (9) and
i.
secure switch handle assembly (12) to front panel flange.
Close door (2).
j.
k.
Secure door to motor controller with two latch screws (1).
l.
On ship service switchboard turn ON STERN WINDLASS circuit breaker and remove
tag.
Turn ON motor controller circuit breaker.
a.
b.
Check motor controller operation. Refer to TM 55-1905-223-10.
2-820
|
||