2-334.
Repair Threaded Fittings.
This task covers: Repair.
At Ship Service Switchboard set
Tool kit, general mechanic's,
BILGE/BALLAST circuit breaker to the
OFF position.  Set FIRE PUMP 1 and
FIRE PUMP 2 circuit breakers to the
Materials/Parts
OFF position. Tag switches 'Out of
Service - Do Not Operate."
Piping system, bilge ballast and
firemain P/N 8529024, refer to
General Safety Instructions
TN 55-1905-223-24P
Anti-seize compound, Item 15,
Appendix C
Warning tags, Item 1, Appendix C
WARNING
Ensure system is turned OFF and
q
tagged to prevent operation during
maintenance.  Generated pressure
could cause injury.
Use extreme care when breaking
q
system connections.  Escaping
pressure and/or fluids could cause
injury.
Clean up spills immediately. Spills
q
create an unsafe working area.'
Refer to paragraph 2-320 for procedures.