TM 55-1905-223-24-18-1
Repair Piping Gauge Assembly.
2-350.
This task covers: Repair.
At the Auxiliary Machinery Motor
Tool kit, general mechanic's,
Control Center, press STOP push-
button on Lube Oil Purifier switch
and set circuit breaker to the OFF
p o s i t i o n .  Press STOP pushbutton on
Dirty Lube Oil pump switch and set
Piping system, compressed air
circuit breaker to the OFF position.
P/N 8262011, refer to
Tag switches "Out of Service - Do
TM 55-1905-223-24P
Not Operate."
Pipe gauge assembly,
P/N 05-2400-0001
Pressure-vacuum gauge (30 vac to
General Safety Instructions
30 PSIG) P/N 33-1035-1075
Pressure gauge (0-200 PSIG)
P/N 33-2150-1075
WARNING
Pressure gauge (0-60 PSIG)
Ensure system is turned OFF and
P/N 33-1650-1075
q
tagged to prevent operation during
Warning tags, Item 1, Appendix C
maintenance.  Generated pressure
Teflon tape, Item 5, Appendix C
could cause injury.
U t i l i t y p a i l , Item 13, Appendix C
Use extreme care when breaking
q
system connections.  Escaping
pressure and/or fluids could cause
injury.
Clean up spills immediately.
q
Spills create an unsafe working
area.
Exercise extreme caution when
q
working with flammables.
Refer to paragraph 2-335 for procedures.
2-1017


 