Custom Search
 
  
 
TM 55-1905-223-24-18-1
Repair Piping Gauge Assembly.
2-355.
Repair.
This task covers:
INITIAL SETUP
Equipment Condtion
Tools
On Oily Water Separator control panel
Tool kit, general mechanic's,
set ON - OFF power switch to OFF.
Tag switch "Out of Service - Do
Not Operate."
Materials/Parts
General Safety Instructions
Piping system, oily water separator
P/N 8529025, refer to
TM 55-1905-223-24P
Piping gauge assembly
WARNING
P/N 05-2400-0001
Ensure system is tagged to prevent
Pressure gauge (O-10 psi)
.
operation during maintenance.
P/N 33-8503-1075
Generated pressure could cause
Warning tags, Item 1, Appendix C
injury.
Teflon tape, Item 5, Appendix C
U t i l i t y p a i l , Item 13, Appendix C
Use extreme care when breaking
l
system connections.  Escaping
pressure and/or fluids could cause
injury.
Clean up spills immediately.
l
Spills create an unsafe working
area.
REPAIR
Refer to paragraph 2-335 for procedures.