Custom Search
 
  
 
TM 55-1905-223-24-18-1
Repair Hydraulic Oil Storage Tank.
2-381.
a. Removal, b. Replacement.
This tank covers:
I N I T I A L SETUP
Equipment Condition
Tools
Hydraulic oil storage tank liquid
Tool kit, general mechanic's,
quantity indicator alarm wiring
disconnected, refer to TM 55-1905-
223-10.
Materials/Parts
Rags, Item 14, Appendix C
Removal
WARNING
To prevent fire hazard or injury to
personnel by slipping, any spilled hydraulic
fluid during repair procedures must be wiped
up with rags immediately
Remove plain hexagon nut (3), lockwasher (2) and machine bolt (1).
a.
Remove plain hexagon nut (9), lockwasher (8) and machine bolt (7).
b.
Remove liquid quantity indicator (5) and gasket material (4, 6).
c.
Remove plain hexagon nut (11) and lockwasher (10).
d.
Remove steel plate (13) and gasket material (12).
e.
REPLACEMENT
Install gasket material (12) and steel plate (18).
a.
Install lockwasher (10) and plain hexagon nut (11).
b.
Install gasket material (4, 6) and liquid quantity indicator (5).
c.
Install machine bolt (7), lockwasher (8) and plain hexagon nut (9).
d.
Install machine bolt (l), lockwasher (2) and plain hexagon nut (3).
e.
Connect hydraulic oil tank liquid quantity indicator alarm wiring.
f.
2-1072


 