Table 3-2. Troubleshooting-CONT
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WASHER MACHINE - CONT
39. Timer does not advance.
STEP 1. Check timer with multimeter.
Replace timer if defective (para. 3-92).
STEP 2. Check pressure switch.
Replace switch if defective (para. 3-92).
40. Constant agitation.
STEP 1. Check timer.
Replace timer if defective (para. 3-92).
STEP 2. Check electrical wiring.
Replace as required.
DRYER
41. Motor does not run.
STEP 1. Check door switch.
Replace switch if defective (para. 3-103).
STEP 2. Check motor push switch.
Replace switch if defective (para. 3-103).
STEP 3. Check motor.
Replace motor if defective (para. 3-107).
STEP 4. Check timer.
Replace timer if defective (para. 3-92).
42. Motor does not stop when door is open.
STEP 1. Check door switch with multimeter.
Replace door switch (para. 3-92).
43. Heater element does not heat or shuts off prematurely.
STEP 1. Check timer with multimeter.
Replace timer if defective (para. 3-103).
STEP 2. Check for air leak around loading door.
Replace seal or catch (para. 3-103).