If any part of mechanical seal is broken or damaged, the complete seal assembly
must be replaced.
(8) Carefully slide mechanical seal (1) off motor shaft and out of pump body.
(9) Remove four machine screws (1) securing pump body to fluid control ring (13).
(10) Separate and remove pump body from motor shaft and fluid control ring.
(11) Remove three pipe plugs (11) from pump body.
(12) Remove four machine screws (12) securing fluid control ring (13) to pump drive motor (14).
(13) Separate and remove fluid control ring (13) and slinger ring from pump drive motor (14)
shaft.
i. Motorized pump (water).
(1) Position motorized pump (14, Figure 3-18) on a clean, flat surface.
(2) Remove six machine screws (7) securing housing (6) to motorized pump.
(3) Separate and remove housing (6) from pump.
(4) Remove pipe plug (8) from housing.
(5) Slide stator (9) off of rotor (5).
(6) Separate rotor (5) from universal joint (3) by using a punch to remove pin (4) Support rotor
when removing pin. Retain pin for assembly.
(7) Separate universal joint (3) from motor shaft by using a punch through outlet port on pump
body to remove pin (2). Retain pin for assembly.
(8) Slide universal joint off of motor shaft and out of motorized pump (14).
NOTE
If any part of mechanical seal is broken or damaged, the complete seal assembly
must be replaced.
(9) Carefully slide mechanical seal (1) off motor shaft and out of motorized pump (14).
(10) Remove four machine screws (11) securing motorized pump (14).
(11) Separate and remove motorized pump (14) and fluid control ring (12) from motor shaft.
(12) Remove pipe plug (10) from motorized pump (14).