Custom Search
 
  
 
TM 55-1905-223-24-18-2
i. Remove float (16) and float rod (8) from bottom of float chamber assembly (4).
j. Remove cotter pin (14).
k. Separate float from float rod.
l. Detach float tag (15) from float chamber assembly.
REPAIR
Repair of level sight indicator VLI-86200-36 consists of replacing gasket (13, Sheet 2), and float tag (15).
ASSEMBLY
a. Position magnetic chamber assembly (1) and float chamber assembly (4) on a clean flat surface.
b. Attach float tag (15) to float chamber assembly.
c. Position float rod (8) over float (16) with cotter pin holes aligned.
d. Install cotter pin (14) and secure float to float rod by separating ends of cotter pin to an angle of
approximately 60 to 90 degrees.
e. Install float rod and float into bottom of float chamber assembly (4) with float rod directed through
float rod hole in mounting flange.
f. Install cotter pin (12) and secure float rod (8) above mounting flange by separating ends of cotter pin
to an angle of approximately 60 to 90 degrees.
g. Position magnet assembly (6) on float rod (8) with cotter pin holes aligned.
h. Install cotter pin (7) and secure magnet assembly to float rod by separating ends of cotter pin to an
angle of 60 to 90 degrees.
i. Position gasket (13) over magnet assembly and onto flat surface of mounting flange, aligned with
mounting capscrew holes.
j.
Position magnetic capscrew assembly (1) over magnet assembly (6) and aligned with mounting
capscrew holes.
k. Install four hex head capscrews (9) with flat washers (10) and lockwashers (11) to secure magnetic
chamber assembly (1) to mounting flange and float chamber assembly (4).
l. Position flag assembly (3, Sheet 1) on magnetic chamber assembly (1).
m. Install two retaining straps (2) and secure flag assembly to magnetic chamber assembly.
3-156


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business