TM 55-1905-223-24-18-2
3-45. Replace/Repair Receiver Module RE-39260.
This task covers:
a. Removal
b. Disassembly
d. Assembly
c. Repair
e. Replacement
INITIAL SETUP :
Tools
Equipment Condition
Tool kit, general mechanic's,
Electrical power to tank level
indicator system turned OFF
at Panel L102. Tag switch
"Out of Service - Do Not
Materials/Parts
Operate."
Receiver module
RE-39260-12/M1-M8-38100/M9-M12-38139
Gasket P/N 37064, 37081, 37047
Meter assembly P/N 43075 (12)
Preformed packing P/N 17287 (2), 23273
Toggle switch P/N MS24659-22D
Sonalert alarm P/N 39713
Card guide P/N 37096 (38)
Printed circuit connector
P/N 32962 (19)
Power supply P/N 38005 (2)
Flasher module P/N 38105 (2)
Circuit card assembly P/N 38100 (15)
Simulator float P/N 37084
Wire wound variable resistor
P/N RVASAYSB252A
Knob P/N 22423
Nonmetallic grommet P/N 30674 (2)
Power transformer P/N 37652 (2),
37653 (2)
Electrolytic fixed capacitor
P/N 37079 (2)
Warning tags, Item 1, Appendix C
REMOVAL (Figure 3-44)
a. Tag and disconnect electrical cable connectors at top of box assembly (4).
b. Remove six plain hex nuts (3), lockwashers (2), and hex head capscrews (1)securing receiver module
box assembly to support mount.
c. Remove box assembly
3-178
|
||