TM 55-1905-223-24-18-2
f. Remove receiver module from mounting rack.
DISASSEMBLY
a. Position receiver module silk screened box (26) on clean, flat surface.
b. Cover (27).
(1) Remove eight machine screws (12) from cover (27) on right side of silk screened box.
(2) Remove cover (27) and cover gasket (28).
c. Remove shock cushion (29) and adhesive (30) from cover (27).
d. Meter (31).
(1) Tag and disconnect electrical leads by removing two plain hex nuts (15) from terminal studs (16) at
rear of meter (31).
(2) Remove four plain hex nuts (15), lockwashers (11), and machine screws (12) securing meter (31) at
front panel.
(3) Remove meter (31) and gasket (32).
e. Toggle switch (53).
(1) Tag and disconnect electrical leads at rear of toggle switch (53).
(2) Remove locking nut (50) from toggle switch (53).
(3) Remove dust and moisture seal boot (52) and toggle switch from rear of front panel.
f. Wirewound variable resistor (51).
(1) Tag and disconnect electrical leads at rear of wirewound variable resistor (51).
(2) Remove locking nut (50) from variable resistor (51).
(3) Remove wirewound variable resistor (51) from rear of front panel.
g. Fuseholder (36).
(1) Tag and disconnect electrical leads at rear of fuseholder (36).
(2) Remove locking nut (50) from fuseholder (36).
(3) Remove alarm control fuse (36) and fuseholder (36) from rear of front panel.