Custom Search
 
  
 
TM 55-1905-223-24-18-2
DISASSEMBLY
a. Remove plain hexagon nut (1, Sheet 1), lockwasher (2), and machine screw (3).
b. Remove plain hexagon nut (5) and lockwasher (6).
c. Tag and disconnect electrical leads. Remove time totalizing meter (4).
d. Remove machine screw (7) and lockwasher (8).
e. Remove plain hexagon nut (10) and lockwasher (11).
f. Tag and disconnect electrical leads. Remove ammeter (9).
g. Remove machine screw (12), lockwasher (13) and plain hexagon nut (14).
h. Tag and disconnect electrical leads. Remove terminal board (20).
i. Remove terminal board marker strip (21).
j. Remove machine screw (18), flat washer (17), lockwasher (16) and plain hexagon nut (15).
k. Remove electrical component tie-down strap (19).
1. Remove plain hexagon nut (26), lockwasher (25) and machine screw.(24).
m. Remove circulating fan (23).
n. Remove plain hexagon nut (28), lockwasher (29) and machine screw (30).
o. Tag and disconnect electrical leads. Remove electromagnetic relay (27) and resistor assembly (22).
p. Remove machine screw (32, Sheet 2) and lockwasher (33).
q. Tag and disconnect electrical leads. Remove terminal board (90) and identification plate (89).
r. Remove machine screw (36) and lockwasher (37).
s. Remove electromagnetic relay (32).
t. Remove machine screw (38), lockwasher (39) and cartridge clamp (40).
u. Remove fixed capacitor (41).
v. Remove machine screw (44) and lockwasher (45).
w. Remove ground lug terminal (43)
x. Remove shaft (42).
3-228


 