a. Remove rotary switch (2).
b. Remove knobs (3, 6).
c. Remove potentiometer (7).
d. Remove knob (4).
e. Remove circuit breaker (5).
f. Remove switchboard assembly (16).
g. Remove start current module assembly (17).
h. Remove post flow module assembly (18).
i. Remove preflow timer assembly (19).
j. Remove ribbon cable assembly (15).
k. Remove remote control assembly (21).
1. Remove capacitor (9) and capacitor bracket (8).
m. Remove capacitor (10) and capacitor bracket (11).
n. Remove resistor (12).
o. Remove resistor (22) and resistor bracket (23).
p. Remove fixed capacitor (20).
q. Remove duplex receptacle (14).
r. Remove transformer (13).
REPAIR
Repair at this level of maintenance is by replacement of: rotary switch (2), circuit breaker (5), preflow
timer assembly (19).
ASSEMBLY
a. Install transformer (13).
b. Install duplex receptacle (14).
c. Install fixed capacitor (20).
d. Install resistor bracket (23) and resistor (22).
e. Install resistor (12).