Custom Search
 
  
 
TM 55-1905-223-24-18-2
j. Remove machine screws (12) and remove thermostatic switch (5).
k. Tag and disconnect electrical leads from indicator light (10).
l. Compress retaining ears and remove indicator light.
REPAIR
Repair at this level of maintenance is by replacement of twin panel plate (2, Sheet 1), temperature
switches (3 and 6) thermostatic switch (5), indicator light (10).
ASSEMBLY
a. Compress retaining ears and install indicator light (10).
b. Remove tags and connect electrical leads.
c. Install thermostatic switch (5) with machine screws (12).
d. Install switch knob (11).
e. Remove tags and connect electrical leads.
f. Install temperature switch (6).
g. Install knob adapter (7) and switch knob (8).
h. Remove tags and connect electrical leads.
i. Install switch panel (9).
j. Install fuse compartment door (4).
k. Install temperature switch (3) for corresponding hot plate (1) mounted in twin panel plate (2).
1. Remove tags and connect electrical leads.
m. Replace solid surface units and the electric range assembly, paragraph 2-54 .