aj. Remove bracket (75).
ak. Remove machine screw (72) and sensitive switch (73).
al. Remove U-clip (74).
am. Remove bracket (77).
an. Remove push nut (79), shield (81), and lever (80).
ao. Remove machine screw (95, Sheet 5) and front panel (96).
ap. Remove machine screw (99) and lug guide (100).
aq. Remove hold-down clip (97).
ar. Remove pad (83).
as. Remove machine screw (85) and sleeve bushing (84).
at. Remove hexagon head capscrew (86) and hinge (89).
au. Remove hexagon head capscrew (87) and ground wire (88).
av. Remove hexagon head capscrew (90) and cabinet (98).
aw. Remove nut (91).
ax. Remove pad (93), leveling leg (92), and lock nut (94) from base (101).
REPAIR
Repair at this level of maintenance is by replacement of rotary switches (4 and 11, Sheet 1), unbalanced load
indicator light (31), in use indicator light (29), rinse indicator light (28), spin indicator light (27), and stop timer
(53, Sheet 2).
ASSEMBLY
a. Install locknut (94), leveling leg (92) and pad (93) on base (101).
b. Install nut (91).
c. Install cabinet (98) on base (101) with hexagon head capscrews (90).
d. Install ground wire (88) and hexagon head capscrew (87).
e. Install hinge (89) and hexagon head capscrew (86).
f. Install sleeve bushing (84) and machine screw (85).
g. Install pad (83).
3-352


 