3-151. Repair Power Distribution Panel P211. (Figure 3-137)
This task covers:
a. Removal
b. Repair
c. Replacement
INITIAL SETUP :
Tools
Equipment Condition
Tool kit, electrician's,
Main switchboard MCHRY SPACES VENT
PANEL P211 125AT/UVT circuit breaker
OFF and tagged "Out of Service - Do
Materials Parts
Not Operate." TM 55-1905-223-10.
Warning tag, Item 1, Appendix C
WARNING
Death, serious injury, or equipment damage can result from
contact with live electrical circuits. Before beginning work on
this, or any other electrical equipment, turn power and control
voltage circuit breakers OFF and tag "Out of Service - Do Not
Operate."
REPAIR
NOTE
Repair of power distribution panel P211 is by replacement of
associated electrical cables (1 through 13).
a. Disconnect cable (1 through 13) from power distribution panel and termination point.
b. Run new cable (1 through 13). Attach to power distribution panel and termination point.