Custom Search
 
  
 
TM 55-1905-223-24-18-2
3-166. Repair Power Distribution.Panel P101 (Figure 3-151).
This task covers:
a. Repair.
INITIAL SETUP :
Tools
Equipment Condition
Tool kit, electrician's,
Main switchboard QTRS HEATER PANEL
P101 125AT UVT circuit breaker Off
and tagged "Out of Service - Do Not
Materials/Parts
Operate." TM 55-1905-223-10.
Warning tags, Item 1, Appendix C
WARNING
Death, serious injury, or equipment damage can result from
contact with live electrical circuits. Before beginning work on
this, or any other electrical equipment, turn power and control
voltage circuit breakers OFF and tag "Out of Service - Do Not
Operate."
REPAIR
NOTE
Repair of power distribution panel P101 is by replacement of
associated electrical cables (1 through 10).
a. Disconnect cable from power distribution panel and termination point.
b. Run new cable. Attach to power distribution panel and termination point.
Change 1 3-552


 