Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-18-2
3-181. Repair Pilot House Battery Assembly. (Figure 3-164)
This task covers:
a. Repair
INITIAL SETUP
Tools
Equipment Condition
Tool kit, electrician's,
AN-VRC-80 BATT CHGR EP109 40AT circuit
breaker OFF and tagged "Out of
Service - Do Not Operate."
Materials/Parts
TM 55-1905-223-10.
Warning tag, Item 1, Appendix C
Transformer P/N lG2Fl-02113A
WARNING
Death, serious injury, or equipment damage can result from
contact with live electrical circuits. Before beginning work on
this, or any other electrical equipment, turn power and control
voltage circuit breakers OFF and tag "Out of Service - Do Not
Operate."
REPAIR
NOTE
Repair of pilot house battery assembly is by replacement of
associated electrical cables (1 through 8) and by repair of
battery charger. Refer to paragraph 3-180 for repair of battery
charger.
a. Disconnect cable from source and termination point.
b. Run new cable. Attach to source and termination point.
Change 1 3-581
|
||