Custom Search
 
  
 
TM 55-1905-223-24-18-2
3-182. Repair Emergency Generator Battery Assembly. (Figure 3-165)
This task covers:
a. Repair
INITIAL SETUP
Tools
Equipment Condition
Tool kit, electrician's,
EMERG GEN BATT CHGR EP113 25AT
circuit breaker OFF and tagged
"Out of Service - Do Not Operate.'
Materials/Parts
TM 55-1905-223-10.
Warning tag, Item 1, Appendix C
Transformer P/N lG2Fl-02113A
WARNING
Death, serious injury, or equipment damage can result from
contact with live electrical circuits. Before beginning work on
this, or any other electrical equipment, turn power and control
voltage circuit breakers OFF and tag "Out of Service - Do Not
Operate."
REPAIR
NOTE
Repair of emergency generator battery assembly is by
replacement of associated electrical cables (1 through 4), and by
repair of battery charger. Refer to paragraph 3-141Q for repair
of battery charger.
a. Disconnect cable from, source and termination point.
b. Run new cable. Attach to source and termination point.
Change 1 3-583


 