3-183. Repair Generator Number 1 Battery Assembly. (Figure 3-166)
This task covers:
Repair
INITIAL SETUP
Tools
Equipment Condition
Tool kit, electrician's,
SSGD-2 BATT CHGR EP112 40AT circuit
breaker OFF and tagged "Out of
Service - Do Not Operate."
TM 55-1905-223-10.
Materials/Parts
Warning tag, Item 1, Appendix C
Transformer P/N 113B1-02717A
WARNING
Death, serious injury, or equipment damage can result from
contact with live electrical circuits. Before beginning work on
this, or any other electrical equipment, turn power and control
voltage circuit breakers OFF and tag "Out of Service - Do Not
Operate."
REPAIR
NOTE
Repair of generator number one battery assembly is by
replacement of associated electrical cables (1 through 3), and
by repair of battery charger. Refer to paragraph 3-141Q for
repair of battery charger.
a. Disconnect cable from source and termination point.
b. Run new cable. Attach to source and termination point.